Microbial Water Quality through a Full-Scale Advanced Wastewater Treatment Demonstration Facility. - Related Documents




#
Rank
Similarity
Title + Abs.
Year
PMID
012345
781501.0000Microbial Water Quality through a Full-Scale Advanced Wastewater Treatment Demonstration Facility. The fates of viruses, bacteria, and antibiotic resistance genes during advanced wastewater treatment are important to assess for implementation of potable reuse systems. Here, a full-scale advanced wastewater treatment demonstration facility (ozone, biological activated carbon filtration, micro/ultrafiltration, reverse osmosis, and advanced oxidation) was sampled over three months. Atypically, no disinfectant residual was applied before the microfiltration step. Microbial cell concentrations and viability were assessed via flow cytometry and adenosine triphosphate (ATP). Concentrations of bacteria (16S rRNA gene), viruses (human adenovirus and JC polyomavirus), and antibiotic resistance genes (sul1 and bla (TEM) ) were assessed via quantitative PCR following the concentration of large sample volumes by dead-end ultrafiltration. In all membrane filtration permeates, microbial concentrations were higher than previously reported for chloraminated membranes, and log(10) reduction values were lower than expected. Concentrations of 16S rRNA and sul1 genes were reduced by treatment but remained quantifiable in reverse osmosis permeate. It is unclear whether sul1 in the RO permeate was from the passage of resistance genes or new growth of microorganisms, but the concentrations were on the low end of those reported for conventional drinking water distribution systems. Adenovirus, JC polyomavirus, and bla (TEM) genes were reduced below the limit of detection (∼10(-2) gene copies per mL) by microfiltration. The results provide insights into how treatment train design and operation choices affect microbial water quality as well as the use of flow cytometry and ATP for online monitoring and process control.202236530600
781610.9996Reduction of antibiotic resistance determinants in urban wastewater by ozone: Emphasis on the impact of wastewater matrix towards the inactivation kinetics, toxicity and bacterial regrowth. This study investigated the impact of bench-scale ozonation on the inactivation of total cultivable and antibiotic-resistant bacteria (faecal coliforms, Escherichia coli, Pseudomonas aeruginosa, Enterococcus spp., and total heterotrophs), and the reduction of gene markers (16S rRNA and intl1) and antibiotic resistance genes (qacEΔ1, sul1, aadA1 and dfrA1) indigenously present in wastewater effluents treated by membrane bioreactor (MBR) or conventional activated sludge (CAS). The Chick-Watson model-predicted ozone exposure (CT) requirements, showed that higher CT values were needed for CAS- than MBR-treated effluents to achieve a 3-log reduction of each microbial group, i.e., ~30 and 10 gO(3) min gDOC(-1) respectively. Ozonation was efficient in inactivating the examined antibiotic-resistant bacteria, and no bacterial regrowth was observed after 72 h. The genes abundance decreased significantly by ozone, but an increase in their abundance was detected 72 h after storage of the treated samples. A very low removal of DOC was achieved and at the same time phyto- and eco-toxicity increased after the ozonation treatment in both wastewater matrices. The gene abundance, regrowth and toxicity results of this study may be of high environmental significance for comprehensive evaluation of ozone and may guide future studies in assessing these parameters for other oxidants/disinfectants.202134329111
781820.9996Ozonation and UV(254)(nm) radiation for the removal of microorganisms and antibiotic resistance genes from urban wastewater. Conventional wastewater treatment has a limited capacity to reduce antibiotic resistant bacteria and genes (ARB&ARG). Tertiary treatment processes are promising solutions, although the transitory inactivation of bacteria may select ARB&ARG. This study aimed at assessing the potential of ozonation and UV(254nm) radiation to inactivate cultivable fungal and bacterial populations, and the selected genes 16S rRNA (common to all bacteria), intI1 (common in Gram-negative bacteria) and the ARG vanA, bla(TEM), sul1 and qnrS. The abundance of the different microbiological parameters per volume of wastewater was reduced by ∼2 log units for cultivable fungi and 16S rRNA and intI1 genes, by∼3-4 log units, for total heterotrophs, enterobacteria and enterococci, and to values close or below the limits of quantification for ARG, for both processes, after a contact time of 30min. Yet, most of the cultivable populations, the 16S rRNA and intI1 genes as well as the ARG, except qnrS after ozonation, reached pre-treatment levels after 3days storage, suggesting a transitory rather than permanent microbial inactivation. Noticeably, normalization per 16S rRNA gene evidenced an increase of the ARG and intI1 prevalence, mainly after UV(254)(nm) treatment. The results suggest that these tertiary treatments may be selecting for ARB&ARG populations.201727072309
781730.9996Effect of alkaline treatment on pathogens, bacterial community and antibiotic resistance genes in different sewage sludges for potential agriculture use. Alkaline treatment is widely used to reduce pathogens in sewage sludge in developing countries and guarantee that it is safe for use in agriculture. The aim of this study was to investigate the effect of alkaline treatment applied to waste-activated (WAS) and Upflow Anaerobic Sludge Blanket (UASB)-sludge on the bacterial community, pathogens (viable helminths eggs and Salmonella spp), and antibiotic resistance genes (ARG). The bacterial community structure was examined through denaturing gel gradient electrophoresis (DGGE), targeting 16S rRNA genes. Polymerase chain reaction (PCR) was applied to evaluate the presence of several ARGs. The conducted alkaline experiment consisted of adding hydrated lime (Ca(OH)(2)) to sewage sludges. Samples were taken before and after 2, 24, 48, and 72 hours of treatment. Alkaline treatment changed considerably the bacterial community structure and after 24 hours, shifts in bacterial profiles were more pronounced in the UASB sludge sample than in WAS. Some bacteria remained under extreme pH conditions (pH > 12), such as Azospira oryzae and Dechloromonas denitrificans in the WAS samples, and Geothrix and Geobacter in the UASB sludge samples. The values of pathogens and indicators in the sludge after 24 hours of alkaline treatment meet sanitary law regulations and thus the sludges could have the potential to agricultural distribution. It is important to highlight that ARG, which are not currently present in sanitary regulations, were detected in the sludge samples after the alkaline treatment, which could be a concern for human health.202030051768
760640.9996Dissemination prevention of antibiotic resistant and facultative pathogenic bacteria by ultrafiltration and ozone treatment at an urban wastewater treatment plant. Conventional wastewater treatment is not sufficient for the removal of hygienically relevant bacteria and achieves only limited reductions. This study focuses on the reduction efficiencies of two semi-industrial ultrafiltration units operating at a large scale municipal wastewater treatment plant. In total, 7 clinically relevant antibiotic resistance genes, together with 3 taxonomic gene markers targeting specific facultative pathogenic bacteria were analysed via qPCR analyses before and after advanced treatment. In parallel with membrane technologies, an ozone treatment (1 g ozone/g DOC) was performed for comparison of the different reduction efficiencies. Both ultrafiltration units showed increased reduction efficiencies for facultative pathogenic bacteria and antibiotic resistance genes of up to 6 log units, resulting mostly in a strong reduction of the bacterial targets. In comparison, the ozone treatment showed some reduction efficiency, but was less effective compared with ultrafiltration due to low ozone dosages frequently used for micro-pollutant removal at municipal wastewater treatment plants. Additionally, metagenome analyses demonstrated the accumulation of facultative pathogenic bacteria, antibiotic resistance genes, virulence factor genes, and metabolic gene targets in the back flush retentate of the membranes, which opens further questions about retentate fluid material handling at urban wastewater treatment plants.201931492933
730550.9996Inactivation of antibiotic-resistant bacteria in hospital wastewater by ozone-based advanced water treatment processes. The emergence and spread of antimicrobial resistance (AMR) continue on a global scale. The impacts of wastewater on the environment and human health have been identified, and understanding the environmental impacts of hospital wastewater and exploring appropriate forms of treatment are major societal challenges. In the present research, we evaluated the efficacy of ozone (O(3))-based advanced wastewater treatment systems (O(3), O(3)/H(2)O(2), O(3)/UV, and O(3)/UV/H(2)O(2)) for the treatment of antimicrobials, antimicrobial-resistant bacteria (AMRB), and antimicrobial resistance genes (AMRGs) in wastewater from medical facilities. Our results indicated that the O(3)-based advanced wastewater treatment inactivated multiple antimicrobials (>99.9%) and AMRB after 10-30 min of treatment. Additionally, AMRGs were effectively removed (1.4-6.6 log(10)) during hospital wastewater treatment. The inactivation and/or removal performances of these pollutants through the O(3)/UV and O(3)/UV/H(2)O(2) treatments were significantly (P < 0.05) better than those in the O(3) and O(3)/H(2)O(2) treatments. Altered taxonomic diversity of microorganisms based on 16S rRNA gene sequencing following the O(3)-based treatment showed that advanced wastewater treatments not only removed viable bacteria but also removed genes constituting microorganisms in the wastewater. Consequently, the objective of this study was to apply advanced wastewater treatments to treat wastewater, mitigate environmental pollution, and alleviate potential threats to environmental and human health associated with AMR. Our findings will contribute to enhancing the effectiveness of advanced wastewater treatment systems through on-site application, not only in wastewater treatment plants (WWTPs) but also in medical facilities. Moreover, our results will help reduce the discharge of AMRB and AMRGs into rivers and maintain the safety of aquatic environments.202437777130
781360.9996A framework predicting removal efficacy of antibiotic resistance genes during disinfection processes with machine learning. Disinfection has been applied widely for the removal of antibiotic resistance genes (ARGs) to curb the spread of antibiotic resistance. Quantitative polymerase chain reaction (qPCR) is the most used method to quantify the damage of DNA thus calculating the ARG degradation during disinfection but suffers the deviation due to the limitation of amplicon length. In contrast, transformation assay more accurately measures ARG deactivation based on expression of disinfected ARG in the receiving bacteria but is typically laborious and material-intensive. This work applied machine learning (ML) to develop a framework by using qPCR results as a proxy to estimate the transformation assay measurements during disinfection with chlorine (FAC), ultraviolet (UV(254)), ozone (O(3)), and hydrogen peroxide/ultraviolet (UV/H(2)O(2)) for multiple kinds of ARGs. ARG degradation rates and deactivation rates were well predicted with the optimal correlation coefficient (R(2)) of all test sets > 0.926 and > 0.871, respectively. Besides, by concatenating the ARG degradation and deactivation predictive models, ARG removal efficiency under given disinfection conditions was directly predicted as the loss of transformation activity with R(2) > 0.828. Furthermore, an online platform was built to provide users with access to the developed ML models for rapid and accurate evaluation of ARG removal efficiency.202540179779
760570.9996Inactivation of antibiotic resistant bacteria and their resistance genes in sewage by applying pulsed electric fields. We evaluated the suitability of pulsed electric field (PEF) technology as a new disinfection option in the sewage treatment plants (STPs) that can inactivate antibiotic resistant bacteria (ARB) and antibiotic resistance genes (ARGs). It was shown that PEF applied disinfection could inactivate not only vancomycin-resistant enterococci (VRE), but also vanA resistance gene. Cultivable VRE could be effectively inactivated by PEF applied disinfection, and were reduced to below the detection limit (log reduction value of VRE > 5 log). Although the vanA also showed a reduction of more than 4 log, it remained in the order of 10(5) copies/mL, suggesting that ARGs are more difficult to be inactivated than ARB in PEF applied disinfection. Among parameters in each applying condition verified in this study, the initial voltage was found to be the most important for inactivation of ARB and ARGs. Furthermore, frequency was a parameter that affects the increase or decrease of the duration time, and it was suggested that the treatment time could be shortened by increasing the frequency. Our results strongly suggested that PEF applied disinfection may be a new disinfection technology option for STPs that contributes to the control of ARB and ARGs contamination in the aquatic environments.202234879573
781980.9996Ozone treatment of conditioned wastewater selects antibiotic resistance genes, opportunistic bacteria, and induce strong population shifts. An ozone treatment system was investigated to analyze its impact on clinically relevant antibiotic resistant bacteria (ARB) and antibiotic resistant genes (ARGs). A concentration of 0.9±0.1g ozone per 1g DOC was used to treat conventional clarified wastewater. PCR, qPCR analyses, Illumina 16S Amplicon Sequencing, and PCR-DGGE revealed diverse patterns of resistances and susceptibilities of opportunistic bacteria and accumulations of some ARGs after ozone treatment. Molecular marker genes for enterococci indicated a high susceptibility to ozone. Although they were reduced by almost 99%, they were still present in the bacterial population after ozone treatment. In contrast to this, Pseudomonas aeruginosa displayed only minor changes in abundance after ozone treatment. This indicated different mechanisms of microorganisms to cope with the bactericidal effects of ozone. The investigated ARGs demonstrated an even more diverse pattern. After ozone treatment, the erythromycin resistance gene (ermB) was reduced by 2 orders of magnitude, but simultaneously, the abundance of two other clinically relevant ARGs increased within the surviving wastewater population (vanA, blaVIM). PCR-DGGE analysis and 16S-Amplicon-Sequencing confirmed a selection-like process in combination with a substantial diversity loss within the vital wastewater population after ozone treatment. Especially the PCR-DGGE results demonstrated the survival of GC-rich bacteria after ozone treatment.201627058129
781490.9996Combination of flow cytometry and molecular analysis to monitor the effect of UVC/H(2)O(2) vs UVC/H(2)O(2)/Cu-IDS processes on pathogens and antibiotic resistant genes in secondary wastewater effluents. The efficiency of a new Advanced Oxidation Process (AOP), namely the photo Fenton like process UV-C/H(2)O(2)/IDS-Cu, in removing determinants of antibiotic resistance and pathogenic bacteria was compared to a consolidated AOP (namely UV-C/H(2)O(2)) in a secondary treated municipal WasteWater (WW). A reductionist experimental laboratory-based approach was applied on real WW and the parameters were collected by an alternative integrated approach using (i) flow cytometry to enumerate bacteria and test for the fitness of the bacterial communities and (ii) molecular analyses to define the community composition (16S rRNA amplicon sequencing) and the abundances of Antibiotic Resistance Genes (ARGs) and of the class 1 integron (intI1 gene) (by quantitative PCR). The same approach was applied also to post-treatment regrowth tests (24 h) to define the potential persistence of the tested parameters. These experiments were performed in both, human pathogens favorable conditions (HPC, in rich medium and 37°C) and in environmental mimicking conditions (EMC, original WW and 20°C). UV-C/H(2)O(2)/IDS-Cu process resulted to be more effective than the UV-C/H(2)O(2)in inactivating bacterial cells in the EMC post-treatment regrowth experiments. Both AOPs were efficiently abating potential human pathogenic bacteria and ARGs in the HPC regrowth experiments, although this trend could not be detected in the measurements taken immediately after the disinfection. In comparison with the UV-C/H(2)O(2), the UV-C/H(2)O(2)/IDS-Cu process did not apparently offer significant improvements in the abatement of the tested parameters in the WW effluent but, by evaluating the results of the regrowth experiments it was possible to extrapolate more complex trends, suggesting contrasting efficiencies visible only after a few hours. This study offers a detailed view on the abatement efficiency of microbiological/genetic parameters for the UV-C/H(2)O(2)/IDS-Cu process, calling for technical adjustments for this very promising technology. At the same time, our results clearly demonstrated the inadequacy of currently applied methodologies in the evaluation of specific parameters (e.g. determinants of antibiotic resistance and pathogenic bacteria) in WW.202032711221
8009100.9996High removal efficiency of antibiotic resistance genes in swine wastewater via nanofiltration and reverse osmosis processes. Swine wastewater treatment plant has become one of the main sources of antibiotic resistance genes (ARGs). Membrane treatment processes are promising solutions for removal of the emerging contaminants. However, limited studies have investigated the effects of nanofiltration and reverse osmosis treatment in removing ARGs in swine wastewater. In this study, the presence and the fate of common ARGs including sul1, sul2, tetA, tetM and tetW, as well as intI1 and 16S rRNA gene, were investigated in a medium-sized (6500) pig farm wastewater treatment plant (WWTP) equipped with conventional biological treatment and advanced membrane processing system. All of the genes were detected with highly abundance in the raw sewage. The biological treatments of the swine wastewater treatment plant did not reduce the quantity of the ARGs. As expected, nanofiltration and reverse osmosis treatment reduced the absolute gene copy number of ARGs efficiently (4.98-9.52 logs removal compared to raw sewage). Compared to the reverse osmosis effluent, however, the absolute abundance of ARGs in the artificial wetland increased by 1.00-2.06 logs. Meanwhile, the relative abundance of sulfonamide resistant genes were basically unchanged, while tetracycline resistance genes (tetA, tetM and tetW) decreased by 0.88, 3.47, 2.51 log, respectively. The results demonstrated that advanced membrane treatments are capable of removing various kinds of ARGs efficiently, as well as some common nitrogen and phosphorus contaminants. This study suggested a mature alternative method for the removal of ARGs from livestock wastewater.201930368154
7445110.9996Efficient removal of antibiotic resistance genes and of enteric bacteria from reclaimed wastewater by enhanced Soil Aquifer Treatments. Soil Aquifer Treatment (SAT) is a robust technology to increase groundwater recharge and to improve reclaimed water quality. SAT reduces dissolved organic carbon, contaminants of emerging concern, nutrients, and colloidal matter, including pathogen indicators, but little is known about its ability to reduce loads of antibiotic resistance genes (ARGs) from reclaimed waters. Here we test six pilot SAT systems to eliminate various biological hazards from the secondary effluents of a wastewater treatment plant (WWTP), equipped with reactive barriers (RBs) including different sorptive materials. Using flow cytometry, qPCR and 16S rRNA gene amplicon sequencing methods, we determined that all six SAT systems reduced total loads of bacteria by 80 to 95 % and of clinically relevant ARGs by 85 to 99.9 %. These efficiencies are similar to those reported for UV/oxidation or membrane-based tertiary treatments, which require much more energy and resources. The presence and composition of reactive barriers, the season of sampling (June 2020, October 2020, and September 2021), or the flow regime (continuous versus pulsating) did not affect ARG removal efficiency, although they did alter the microbial community composition. This suggests that an adequate design of the SAT reactive barriers may significantly increase their performance. Under a mechanistic point of view, we observed an ecological succession of bacterial groups, linked to the changing physical-chemical conditions along the SAT, and likely correlated to the removal of ARGs. We concluded that SAT is as cost-efficient technology able to dramatically reduce ARG loads and other biological hazards from WWTP secondary effluents.202439244046
7185120.9996Relationship between modification of activated sludge wastewater treatment and changes in antibiotic resistance of bacteria. Biological treatment processes at wastewater treatment plants (WWTPs), which are the most common methods of sewage treatment, could cause selective elimination and/or changes in the proportions of phenotypes/genotypes within bacterial populations in effluent. Therefore, WWTPs based on activated sludge used in sewage treatment constitute an important reservoir of enteric bacteria which harbour potentially transferable resistance genes. Together with treated wastewater, these microorganisms can penetrate the soil, surface water, rural groundwater supplies and drinking water. Because of this, the aim of this study was to determine the impact of various modification of sewage treatment (the conventional anaerobic/anoxic/oxic (A2/O) process, mechanical-biological (MB) system, sequencing batch reactors (SBR), mechanical-biological system with elevated removal of nutrients (MB-ERN)) on the amount of antibiotic resistant bacteria (ARB) (including E. coli) and antibiotic resistance genes (ARGs) in sewage flowing out of the 13 treatment plants using activated sludge technology. There were no significant differences in ARB and ARGs regardless of time of sampling and type of treated wastewater (p > 0.05). The highest percentage of reduction (up to 99.9%) in the amount of ARB and ARGs was observed in WWTPs with MB and MB-ERN systems. The lowest reduction was detected in WWTPs with SBR. A significant increase (p < 0.05) in the percentage of bacteria resistant to the new generation antibiotics (CTX and DOX) in total counts of microorganisms was observed in effluents (EFF) from WWTPs with A2/O system and with SBR. Among all ARGs analyzed, the highest prevalence of ARGs copies in EFF samples was observed for sul1, tet(A) and qepA, the lowest for bla(TEM) and bla(SHV). Although, the results of presented study demonstrate high efficiency of ARB and ARGs removal during the wastewater treatment processes, especially by WWTPs with MB and MB-ERN systems, EFF is still an important reservoir of ARGs which can be transferred to other microorganisms.201829791883
7194130.9995Response of antibiotic resistance genes in constructed wetlands during treatment of livestock wastewater with different exogenous inducers: Antibiotic and antibiotic-resistant bacteria. This work aimed to study the behavior of antibiotic resistance genes (ARGs) in constructed wetlands with different exogenous inducers additions (oxytetracycline and its resistant bacteria) by high-throughput quantitative polymerase chain reaction. Results indicated that constructed wetlands have the potential to reduce ARGs relative abundances in wastewater, and the total ARGs removal efficiency could exceed 60%. ARGs profile in the effluent differed from that in the influent, and that did not directly reflect the export of dominant ARGs in wetland biofilms. Meanwhile, the highest levels of detected numbers and relative abundances of ARGs were 43 and 3.35 × 10(-1) for control system and 44 and 6.40 × 10(-1) for treatment system, respectively, which meant that ARGs generation in wetlands were inevitable, and antibiotic and antibiotic-resistant bacteria from wastewater could indeed promote ARGs abundance in the system. Compared to the single roles of inducers, their synergistic role had a more significant influence on ARGs relative abundance.202032652450
7844140.9995Insight into using a novel ultraviolet/peracetic acid combination disinfection process to simultaneously remove antibiotics and antibiotic resistance genes in wastewater: Mechanism and comparison with conventional processes. In this study, the simultaneous removal mechanism of antibiotics and antibiotic resistance genes (ARGs) was investigated using the novel ultraviolet/peracetic acid (UV/PAA) combination disinfection process and conventional disinfection processes were also applied for comparison. The results showed that UV/PAA disinfection with a high UV dosage (UV/PAA-H) was most effective for the removal of tetracyclines, quinolones, macrolides and β-lactams; their average removal efficiencies ranged from 25.7% to 100%, while NaClO disinfection was effective for the removal of sulfonamides (∼81.6%). The majority of ARGs were well removed after the UV/PAA-H disinfection, while specific genes including tetB, tetC, ermA and bla(TEM) significantly increased after NaClO disinfection. In addition, β-lactam resistance genes (-35.9%) and macrolides resistance genes (-12.0%) remarkably augmented after UV/NaClO disinfection. The highly reactive oxidation species generated from UV/PAA process including hydroxyl radicals (•OH) and carbon-centered organic radicals (R-C•), were responsible for the elimination of antibiotics and ARGs. Correlation analysis showed that tetracycline, sulfonamide and macrolide antibiotics removal showed a positive correlation with the corresponding ARGs, and a low dose of antibiotic residues played an important role in the distribution of ARGs. Metagenomic sequencing analysis showed that UV/PAA disinfection could not only greatly decrease the abundance of resistant bacteria but also downregulate the expression of key functional genes involved in ARGs propagation and inhibit the signal transduction of the host bacteria, underlying that its removal mechanism was quite different from that of NaClO-based disinfection processes. Our study provides valuable information for understanding the simultaneous removal mechanism of antibiotics and ARGs in wastewater during the disinfection processes, especially for the novel UV/PAA combination process.202234982977
7572150.9995Stormwater runoff treatment through electrocoagulation: antibiotic resistant bacteria removal and its transmission risks. Recently, increasing attention has been paid to antibiotic resistant bacteria (ARB) in stormwater runoff. However, there were little data on ARB removal through electrocoagulation (EC) treatment. In this study, batch experiments were conducted to investigate key designs for ARB removal, role of SS, effects of water matrix, and potential risks after EC treatment under the pre-determined conditions. EC treatment with 5 mA/cm(2) of current density and 4 cm of inter-electrode distance was optimal with the highest ARB removal (3.04 log reduction for 30 min). The presence of SS significantly improved ARB removal during EC treatment, where ARB removal increased with the increase of SS levels when SS less than 300 mg/L. Large ARB removal was found under particles with size lower than 150 μm with low contribution (less than 10%) of the settlement without EC treatment, implying that the enhancement of ARB adsorption onto small particles could be one of the reasonable approaches for ARB removal through EC treatment. ARB removal increased firstly and then decreased with the increase of pH, while had proportional relationship with conductivity. After the optimal condition, there were weak conjugation transfer but high transformation frequency (5.5 × 10(-2) for bla(TEM)) for target antibiotic resistance genes (ARGs), indicating that there could be still a risk of antibiotic resistance transformation after EC treatment. These suggested that the combination of EC and other technologies (like electrochemical disinfection) should be potential ways to control antibiotic resistance transmission through stormwater runoff.202436848218
7580160.9995Inactivation of antibiotic resistance genes in antibiotic fermentation residues by ionizing radiation: Exploring the development of recycling economy in antibiotic pharmaceutical factory. Antibiotic fermentation residues are a kind of hazardous waste due to the existence of the residual antibiotics and the potential risk to generate antibiotics resistance genes (ARGs). The appropriate treatment and disposal of antibiotic fermentation residues is imperative. In this study ionizing radiation was applied to treat the antibiotic fermentation residues and the removal efficiencies of antibiotic (erythromycin), ARGs (ermB and ermF) and antibiotic resistant bacteria were investigated. The experimental results showed that erythromycin A content in antibiotic fermentation residues decreased by 86% when the dose was 10 kGy. Moreover, the abundance of ermB and ermF reduced by 89% and 98% at 10 kGy irradiation. Over 99% of total bacteria was removed and antibiotic resistant bacteria (ARB) were less than detection limit after 10 kGy irradiation. Ionizing radiation process is a promising technology for simultaneously removing antibiotic and inactivating ARGs and ARB in antibiotic fermentation residues. Moreover, the irradiation at 10 kGy had no significant influence on the macromolecules organic matters (protein, polysaccharides) of the antibiotic fermentation residues, suggesting that the treated fermentative residues can be used as fertilizer, which could provide the technical support for the development of recycling economy in antibiotic pharmaceutical factory.201930691886
7181170.9995Effects of UVC doses on the removal of antimicrobial resistance elements from secondary treated sewage. Wastewater treatment plants (WWTPs) currently face major challenges toward the removal of microcontaminants and/or microbial matrices and consequently play an important role in the potential dissemination of biological resistance in freshwater. The ultraviolet (UV) system is a tertiary treatment strategy increasingly applied worldwide, although many studies have shown that disinfected effluent can still contain antibiotic-resistant bacteria and resistance genes. Therefore, to better understand the effects of UV radiation doses on the removal of all resistance elements (antibiotics, antibiotic-resistant bacteria, and antibiotic resistance genes), the present study was designed using a pilot-scale photoreactor. The UV doses could be varied to investigate whether there is an optimal UV dose capable of removing all resistance elements and also if the UV dose frequently applied in full-scale systems is able to reduce the resistance elements. The effect of different UV doses (A, 0-10 mJ/cm(2); B, 10-15 mJ/cm(2); and C, > 15 mJ/cm(2)) in a pilot-scale photoreactor on the removal of antibiotics, antibiotic-resistant bacteria, and genes from the effluent of a UASB reactor followed by a biological trickling filter system (UASB-TF) fed with real sanitary sewage was investigated. Samples of influent and effluent from the UVC photoreactor were collected, and the concentration levels of norfloxacin (NOR), ciprofloxacin (CIP), and levofloxacin (LEV) were assessed. The qnrB, sul1, ermB, integron-integrase (intI1), and 16S rRNA genes, total heterotrophic bacteria (THB), and bacterial resistance to azithromycin and sulfamethoxazole were also investigated. Results indicated that LEV and intI1 were found in the highest median concentrations in the photoreactor influent. Although most antibiotics (NOR and CIP) and ARGs (intI1, 16S rRNA, and qnrB) were apparently better removed with the highest UV dose (> 15 mJ/cm(2)) applied, except for LEV, sul1, and ermB genes, the Kruskal-Wallis test reported no significant difference between low and high doses. ARB removal (from 80 to 100%) was observed at all UV doses. Principal component analysis (PCA) suggested a clear pattern of pollutant groups, i.e., antibiotics, ARG, and ARB, which exhibited low (median of 8-16%), medium (37-96%), and high (> 97%) removal percentages, respectively. These results demonstrated that UVC photoreactors can be an alternative to complement biological treatment in sewage treatment plants at the dose normally applied in full-scale WWTPs (> 15 mJ/cm(2)). However, there was no optimal single dose capable of removing all the resistance elements investigated.202539873874
7192180.9995Sulfamethoxazole and COD increase abundance of sulfonamide resistance genes and change bacterial community structures within sequencing batch reactors. The abundant microbial community in biological treatment processes in wastewater treatment plants (WWTPs) may potentially enhance the horizontal gene transfer of antibiotic resistance genes with the presence of antibiotics. A lab-scale sequencing batch reactor was designed to investigate response of sulfonamide resistance genes (sulI, sulII) and bacterial communities to various concentrations of sulfamethoxazole (SMX) and chemical oxygen demand (COD) of wastewater. The SMX concentrations (0.001 mg/L, 0.1 mg/L and 10 mg/L) decreased with treatment time and higher SMX level was more difficult to remove. The presence of SMX also significantly reduced the removal efficiency of ammonia nitrogen, affecting the normal function of WWTPs. All three concentrations of SMX raised both sulI and sulII genes with higher concentrations exhibiting greater increases. The abundance of sul genes was positive correlated with treatment time and followed the second-order reaction kinetic model. Interestingly, these two genes have rather similar activity. SulI and sulII gene abundance also performed similar response to COD. Simpson index and Shannon-Weiner index did not show changes in the microbial community diversity. However, the 16S rRNA gene cloning and sequencing results showed the bacterial community structures varied during different stages. The results demonstrated that influent antibiotics into WWTPs may facilitate selection of ARGs and affect the wastewater conventional treatment as well as the bacteria community structures.201728211331
7300190.9995Propensity of activated sludge to amplify or attenuate tetracycline resistance genes and tetracycline resistant bacteria: a mathematical modeling approach. The overall goal of this study was to quantify the propensity of the activated sludge (AS) process at three wastewater treatment plants (WWTP) to amplify or attenuate tetracycline resistant bacteria (TRB) and tetracycline resistance genes (TRG). Accordingly, the abundance and fraction of TRB and seven TRG in different unit operations of these WWTP were analytically measured and modeled using a mass balance approach widely used for AS design. Based on the model, the AS process of the different WWTP neither amplified nor attenuated the TRB and TRG fractions. Of the TRG tested, the ribosomal protection genes, tet(O) and tet(W) were the most abundant, along the treatment train of the WWTP, on all sampling dates and sampling locations. Significant amounts of TRB and TRG were discharged in the effluent streams. Notably, in selected samples, the fraction of TRB increased in response to ultraviolet disinfection of treated wastewater compared to chlorination. This study therefore implicates wastewater treatment processes as significant point sources of tetracycline resistance determinants to the environment, and provides a mathematical basis to compute the production capacity of these determinants in the AS process.201020096919