Investigation of reduction in risk from antibiotic resistance genes in laboratory wastewater by using O(3) , ultrasound, and autoclaving. - Related Documents




#
Rank
Similarity
Title + Abs.
Year
PMID
012345
779101.0000Investigation of reduction in risk from antibiotic resistance genes in laboratory wastewater by using O(3) , ultrasound, and autoclaving. Biological laboratory wastewater containing both antibiotic-resistant bacteria (ARB) and antibiotics is a potential source of antibiotic resistance genes (ARGs). Thus, we determined the efficacy of autoclaving, a common disinfection method, in eliminating 5 ARGs (sul1, sul2, tetW, tetM, amp) and the integrase-encoding gene intI1 from laboratory wastewater. Autoclaving (15 min, 121°C) inactivated all bacteria including ARB, whereas ARGs persisted in the wastewater with limited reduction even after 60 min of treatment. Ozonation (O(3) ), ultrasound (US), O(3) /US, and autoclaving followed by O(3) were investigated for their ability to reduce ARGs in laboratory wastewater. With O(3) and O(3) /US, the reduction rate ranged from 5.44 to 7.13 log for all ARGs investigated. Wastewater treatment with US alone did not reduce ARGs under the present experimental conditions (150 W, 53 kHz). Among the four treatments, autoclaving followed by O(3) treatment showed the highest reduction rates in the shortest time; however, further optimization and investigation are needed for the advanced treatment of bio-laboratory wastewater. Overall, this study provides novel insights into ARG sources and demonstrates that advanced oxidation methods can be useful to optimize laboratory wastewater treatment for ARG inactivation. PRACTITIONER POINTS: Bio-laboratory wastewater is potential reservoir of ARGs. Conventional autoclaving was not able to reduce ARGs to a low level. Autoclaving-O(3) completely eliminate all the bacteria. Autoclaving-O(3) reduced ARGs efficiently (6.12-7.86 logs removal in 60 min).202132891064
784710.9998Inactivation and change of tetracycline-resistant Escherichia coli in secondary effluent by visible light-driven photocatalytic process using Ag/AgBr/g-C(3)N(4). Control of antibiotic-resistant bacteria (ARB) and their related genes in secondary effluents has become a serious issue because of increased awareness of their health risks. A considerable number of techniques have been developed in recent years, particularly in relation to advanced oxidation. However, limited information is known about cellular behavior and resistance characteristic change during photocatalytic treatment. In this study, the inactivation of tetracycline (TC)-resistant Escherichia coli (TC-E. coli), removal of TC-resistant genes (TC-RGs), and antibiotic susceptibility were evaluated by employing photocatalytic treatment using Ag/AgBr/g-C(3)N(4) with visible light irradiation. The effects of light intensity, photocatalyst dosage, and reaction ambient temperature on photocatalysis were modelled and investigated. The rate of TC-E. coli removal was also optimized. Results demonstrated that the optimal conditions for TC-E. coli removal included light intensity of 96.0 mW/cm(2), photocatalyst dosage of 211.0 mg/L, and reaction ambient temperature of 23.7 °C. Under such conditions, the ARB removal rate was 6.1 log after 90 min and the related TC-RG removal rates were 49%, 86%, 69%, and 86% for tetA, tetM, tetQ, and intl1, respectively. The minimum inhibitory concentration test after photocatalysis shows that the antibiotic resistance of TC-E. coli was enhanced, which may be mainly due to the changes in the membrane potential and resulted in difficulty in destroying the bacteria through antibiotic contact. Hence, photocatalytic treatment could be an ideal method for ARB and antibiotic-resistant gene (ARG) control in wastewater, but the health risks of the remaining ARB and ARG should be investigated further.202031841919
779520.9998Factors influencing the removal of antibiotic-resistant bacteria and antibiotic resistance genes by the electrokinetic treatment. The performance of the electrokinetic remediation process on the removal of antibiotic-resistant bacteria (ARB) and antibiotic resistance genes (ARGs) was evaluated with different influencing factors. With chlortetracycline (CTC), oxytetracycline (OTC), and tetracycline (TC) as template chemicals, the removal of both ARB and ARGs was enhanced with the increase of voltage gradient (0.4-1.2 V cm(-1)) and prolonged reaction time (3-14 d). The greatest removal (26.01-31.48% for ARB, 37.93-83.10% for ARGs) was obtained applying a voltage of 1.2 V cm(-1), leading to the highest electrical consumption. The effect of polarity reversal intervals on the inactivation ratio of ARB followed the order of 0 h (66.06-80.00%) > 12 h (17.07-24.75%) > 24 h (10.44-13.93%). Lower pH, higher current density, and more evenly-distributed voltage drop was observed with a polarity reversal interval of 12 h compared with that of 24 h, leading to more efficient electrochemical reactions in soil. Compared with sul genes, tet genes were more vulnerable to be attacked in an electric field. It was mainly attributed to the lower abundance of tet genes (except tetM) and the varied effects of electrokinetic remediation process on different ARGs. Moreover, a relatively less removal ratio of tetC and tetG was obtained mainly due to the mechanism of the efflux pump upregulation. Both tet and sul genes were positively correlated with TC-resistant bacteria. The efflux pump genes like tetG and the cellular protection genes like tetM showed different correlations with ARB. This study enhances the current understanding on the removal strategies of ARB and ARGs, and it provides important parameters for their destruction by the electrokinetic treatment.201829807293
776330.9998Antibiotic resistance genes fate and removal by a technological treatment solution for water reuse in agriculture. In order to mitigate the potential effects on the human health which are associated to the use of treated wastewater in agriculture, antibiotic resistance genes (ARGs) are required to be carefully monitored in wastewater reuse processes and their spread should be prevented by the development of efficient treatment technologies. Objective of this study was the assessment of ARGs reduction efficiencies of a novel technological treatment solution for agricultural reuse of municipal wastewaters. The proposed solution comprises an advanced biological treatment (Sequencing Batch Biofilter Granular Reactor, SBBGR), analysed both al laboratory and pilot scale, followed by sand filtration and two different disinfection final stages: ultraviolet light (UV) radiation and peracetic acid (PAA) treatments. By Polymerase Chain Reaction (PCR), the presence of 9 ARGs (ampC, mecA, ermB, sul1, sul2, tetA, tetO, tetW, vanA) were analysed and by quantitative PCR (qPCR) their removal was determined. The obtained results were compared to the reduction of total bacteria (16S rDNA gene) and of a faecal contamination indicator (Escherichia coli uidA gene). Only four of the analysed genes (ermB, sul1, sul2, tetA) were detected in raw wastewater and their abundance was estimated to be 3.4±0.7 x10(4) - 9.6±0.5 x10(9) and 1.0±0.3 x10(3) to 3.0±0.1 x10(7) gene copies/mL in raw and treated wastewaters, respectively. The results show that SBBGR technology is promising for the reduction of ARGs, achieving stable removal performance ranging from 1.0±0.4 to 2.8±0.7 log units, which is comparable to or higher than that reported for conventional activated sludge treatments. No reduction of the ARGs amount normalized to the total bacteria content (16S rDNA), was instead obtained, indicating that these genes are removed together with total bacteria and not specifically eliminated. Enhanced ARGs removal was obtained by sand filtration, while no reduction was achieved by both UV and PAA disinfection treatments tested in our study.201627450254
779440.9997Fate of antibiotic resistant bacteria and genes during wastewater chlorination: implication for antibiotic resistance control. This study investigated fates of nine antibiotic-resistant bacteria as well as two series of antibiotic resistance genes in wastewater treated by various doses of chlorine (0, 15, 30, 60, 150 and 300 mg Cl2 min/L). The results indicated that chlorination was effective in inactivating antibiotic-resistant bacteria. Most bacteria were inactivated completely at the lowest dose (15 mg Cl2 min/L). By comparison, sulfadiazine- and erythromycin-resistant bacteria exhibited tolerance to low chlorine dose (up to 60 mg Cl2 min/L). However, quantitative real-time PCRs revealed that chlorination decreased limited erythromycin or tetracycline resistance genes, with the removal levels of overall erythromycin and tetracycline resistance genes at 0.42 ± 0.12 log and 0.10 ± 0.02 log, respectively. About 40% of erythromycin-resistance genes and 80% of tetracycline resistance genes could not be removed by chlorination. Chlorination was considered not effective in controlling antimicrobial resistance. More concern needs to be paid to the potential risk of antibiotic resistance genes in the wastewater after chlorination.201525738838
800350.9997Dynamics of antibiotic resistance agents during sludge alkalinization treatment. This study aimed to assess the removal of antimicrobial resistance agents (antibiotics, antibiotic-resistant bacteria - ARB, and antimicrobial resistance genes - ARGs) from aerobic and anaerobic sludges treated with quicklime (chemical alkalinization). Different mixing ratios (25%, 35%, and 45%) and contact times (2 h and 72 h) were evaluated. The findings revealed that anaerobic sludge responded more effectively to alkaline treatment, achieving better removal rates of antibiotics, ARB, and ARGs compared to aerobic sludge. The 45% lime treatment yielded the highest antibiotic removal rates, with average reductions of 19% in aerobic sludge and 28% in anaerobic sludge. The 35% lime treatment was the most effective in reducing ARGs across both types of sludge (average removal of 2 logs). The 25% lime treatment proved most efficient for removing ARB, with average reductions of 4 logs (aerobic) and 5 logs (anaerobic). The contact time between the sludge and quicklime also influenced the removal of resistance agents. An increase in the proportion of antibiotics and the absolute concentration of ARB and ARGs was observed after 72 h compared to the samples analyzed after 2 h of contact. This increase was more pronounced in aerobic sludge samples treated with 35% and 45% lime. Despite the overall reduction, none of the monitored resistant genes or bacteria were completely eradicated in both sludge samples, raising concerns about their potential dissemination into the environment.202439414064
803560.9997Effects of hydrothermal treatment on the reduction of antibiotic-resistant Escherichia coli and antibiotic resistance genes and the fertilizer potential of liquid product from cattle manure. In this study, the reduction in the abundance of antibiotic-resistant bacteria (ARB) and antibiotic resistance genes (ARGs) and the fertilizer potential of liquid products from hydrothermally treated cattle manure were investigated. Hydrothermal treatment (HTT) was conducted under different reaction temperatures (125, 150, 175 and 200 °C) and retention times (60, 90 and 120 min). The total organic carbon (TOC) and total nitrogen (TN) of the liquid product increased with increasing reaction temperature. The germination index (GI), a measure of the percentage of germination, exceeded 90 % at 125, 150, and 175 °C in diluted samples, while it decreased to 18 % at 200 °C. Although a longer retention time contributed to an increase in TOC of liquid products, it did not increase the GI values. The liquid product should be diluted or adjusted before use as fertilizer to prevent phytotoxicity. In our analysis of ARB and ARGs, E. coli and antibiotic-resistant E. coli were completely reduced after HTT, except for the operating conditions of 125 °C and 60 min. Although both a higher reaction temperature and longer retention time tended to be better for the reduction of ARGs and intI1, it was found that the longer retention time is much more effective than the higher reaction temperature. The reduction of target ARGs and intI1 was 2.9-log under175 °C and 120 min. Comprehensively considering the fertilizer potential of liquid product and the reduction of ARB and ARGs, 175 °C of reaction temperature and 120 min of retention time of operating conditions for HTT were recommended.202438744164
725070.9997Effect of temperature on the fate of genes encoding tetracycline resistance and the integrase of class 1 integrons within anaerobic and aerobic digesters treating municipal wastewater solids. The objective of this research was to investigate the ability of anaerobic and aerobic digesters to reduce the quantity of antibiotic resistant bacteria in wastewater solids. Lab-scale digesters were operated at different temperatures (22 °C, 37 °C, 46 °C, and 55 °C) under both anaerobic and aerobic conditions and fed wastewater solids collected from a full-scale treatment facility. Quantitative PCR was used to track five genes encoding tetracycline resistance (tet(A), tet(L), tet(O), tet(W), and tet(X)) and the gene encoding the integrase (intI1) of class 1 integrons. Statistically significant reductions in the quantities of these genes occurred in the anaerobic reactors at 37 °C, 46 °C, and 55 °C, with the removal rates and removal efficiencies increasing as a function of temperature. The aerobic digesters, in contrast, were generally incapable of significantly decreasing gene quantities, although these digesters were operated at much shorter mean hydraulic residence times. This research suggests that high temperature anaerobic digestion of wastewater solids would be a suitable technology for eliminating various antibiotic resistance genes, an emerging pollutant of concern.201021058743
718280.9997Effects of UV disinfection on phenotypes and genotypes of antibiotic-resistant bacteria in secondary effluent from a municipal wastewater treatment plant. To elucidate the effects of UV disinfection on antibiotic resistance in biologically-treated wastewater, we investigated the antibiotic resistance profiles, species of cultivable heterotrophic bacteria, and antibiotic-resistance genes (ARGs) in antibiotic-resistant bacteria before and after treatment. UV disinfection greatly changed the bacterial community structure and the antibiotic resistance in wastewater. The antibiotic resistance in wastewater samples was strongly associated with the bacterial community. The proportions of Gram-positive bacteria gradually increased with increasing UV fluence. The proportions of bacteria resistant to cephalexin, penicillin, and vancomycin all greatly decreased after UV treatment in both sampling events (July 2018 and January 2019), and those for bacteria resistant to ofloxacin, ciprofloxacin, and sulfadiazine increased, resulting from the alternative antibiotic resistance profiles among different genera. UV disinfection induced the selection of multi-antibiotic resistant (MAR) bacteria. For example, the MAR indices of Aeromonas, the dominant genus during the treatments, were significantly increased after UV irradiation (P < 0.05). The MAR index was also markedly increased (P < 0.05) at a fluence of 5 mJ/cm(2) in both events. In UV10 treatment, the bacterial community structure was greatly changed. The genera with relatively low MAR indices replaced that with high MAR indices, and became the dominant genera. As a result, the MAR indices of treated samples showed a decreased trend after 10 mJ/cm(2) UV irradiation. The detection frequencies of ARGs located on the chromosome varied mainly due to the evolution of the microbial community. The occurrence of ARGs (tetA, tetC, tetM, tetW, tetX, and sul1) located on plasmid DNA decreased after UV disinfection, and the average detection frequencies of tet and sul genes decreased by 15% and 6%, respectively (P < 0.05). Generally speaking, the effect of UV disinfection on the enrichment of antibiotic resistance is limited in this study, and horizontal gene transfer via the plasmids in surviving bacteria might be impaired due to the decreased abundance of ARGs on the plasmids.201930991178
720490.9997Solar-light driven photodegradation of antimicrobials, their transformation by-products and antibiotic resistance determinants in treated wastewater. This study aimed to assess the possibility of using solar light-driven photolysis and TiO(2)-based photocatalysis to remove (1) antibiotic residues, (2) their transformation products (TPs), (3) antibiotic resistance determinants, and (4) genes identifying the indicator bacteria in a treated wastewater (secondary effluent). 16 antimicrobials belonging to the different classes and 45 their transformation by-products were selected for the study. The most susceptible to photochemical decomposition was tetracycline, which was completely removed in the photocatalysis process and in more than 80% in the solar light-driven photolysis. 83.8% removal (on average) was observed using photolysis and 89.9% using photocatalysis in the case of the tested genes, among which the genes sul1, uidA, and intI1 showed the highest degree of removal by both methods. The study revealed that applied methods promisingly remove the tested antibiotics, their TPs and genes even in such a complex matrix including treated wastewater and photocatalysis process had a higher removal efficiency of antibiotics, TPs and genes tested. Moreover, the high percentage removal of the intI1 gene (>93%) indicates the possibilities of use of the solar light-driven photolysis and TiO(2)-based photocatalysis in minimizing the antibiotic resistance genes transfer by mobile genetic elements.202235469868
7572100.9997Stormwater runoff treatment through electrocoagulation: antibiotic resistant bacteria removal and its transmission risks. Recently, increasing attention has been paid to antibiotic resistant bacteria (ARB) in stormwater runoff. However, there were little data on ARB removal through electrocoagulation (EC) treatment. In this study, batch experiments were conducted to investigate key designs for ARB removal, role of SS, effects of water matrix, and potential risks after EC treatment under the pre-determined conditions. EC treatment with 5 mA/cm(2) of current density and 4 cm of inter-electrode distance was optimal with the highest ARB removal (3.04 log reduction for 30 min). The presence of SS significantly improved ARB removal during EC treatment, where ARB removal increased with the increase of SS levels when SS less than 300 mg/L. Large ARB removal was found under particles with size lower than 150 μm with low contribution (less than 10%) of the settlement without EC treatment, implying that the enhancement of ARB adsorption onto small particles could be one of the reasonable approaches for ARB removal through EC treatment. ARB removal increased firstly and then decreased with the increase of pH, while had proportional relationship with conductivity. After the optimal condition, there were weak conjugation transfer but high transformation frequency (5.5 × 10(-2) for bla(TEM)) for target antibiotic resistance genes (ARGs), indicating that there could be still a risk of antibiotic resistance transformation after EC treatment. These suggested that the combination of EC and other technologies (like electrochemical disinfection) should be potential ways to control antibiotic resistance transmission through stormwater runoff.202436848218
7824110.9997H(2)O(2) and/or TiO(2) photocatalysis under UV irradiation for the removal of antibiotic resistant bacteria and their antibiotic resistance genes. Inactivating antibiotic resistant bacteria (ARB) and removing antibiotic resistance genes (ARGs) are very important to prevent their spread into the environment. Previous efforts have been taken to eliminate ARB and ARGs from aqueous solution and sludges, however, few satisfying results have been obtained. This study investigated whether photocatalysis by TiO(2) was able to reduce the two ARGs, mecA and ampC, within the host ARB, methicillin-resistant Staphylococcus aureus (MRSA) and Pseudomonas aeruginosa, respectively. The addition of H(2)O(2) and matrix effect on the removal of ARB and ARGs were also studied. TiO(2) thin films showed great effect on both ARB inactivation and ARGs removal. Approximately 4.5-5.0 and 5.5-5.8 log ARB reductions were achieved by TiO(2) under 6 and 12mJ/cm(2) UV(254) fluence dose, respectively. For ARGs, 5.8 log mecA reduction and 4.7 log ampC reduction were achieved under 120mJ/cm(2) UV(254) fluence dose in the presence of TiO(2). Increasing dosage of H(2)O(2) enhanced the removal efficiencies of ARB and ARGs. The results also demonstrated that photocatalysis by TiO(2) was capable of removing both intracellular and extracellular forms of ARGs. This study provided a potential alternative method for the removal of ARB and ARGs from aqueous solution.201727776873
7846120.9997Removal of antibiotic resistance genes and inactivation of antibiotic-resistant bacteria by oxidative treatments. The persistence of antibiotics in the environment because of human activities, such as seafood cultivation, has attracted great attention as they can give rise to antibiotic resistance genes (ARGs) and antibiotic-resistant bacteria (ARB). In this study, we explored the inactivation and removal efficiencies of Escherichia coli SR1 and sul1 (plasmid-encoded ARGs), respectively, in their extracellular and intracellular forms (eARGs and iARGs) by three commonly used fishery oxidants, namely chlorine, bromine, and potassium permanganate (KMnO(4)), at the practical effective concentration range (0.5, 5, and 15 mg/L). Kinetics data were obtained using laboratory phosphate-buffered saline (PBS). Following the same fishery oxidation methods, the determined kinetics models were tested by studying the SR1 and sul1 disinfection efficiencies in (sterilized) pond water matrix. At concentrations of 5 and 15 mg/L, all three oxidants achieved sufficient cumulative integrated exposure (CT values) to completely inactivate SR1 and efficiently remove sul1 (up to 4.0-log). The oxidation methods were then applied to an unsterilized pond water matrix in order to study and evaluate the indigenous ARB and ARGs disinfection efficiencies in aquaculture, which reached 1.4-log and 1.0-log during treatment with fishery oxidants used in pond preparation at high concentrations before stocking (5-15 mg/L), respectively. A high chlorine concentration (15 mg/L) could efficiently remove ARGs (or iARGs) from pond water, and the iARG removal efficiency was higher than that of eARGs in pond water. The method and results of this study could aid in guiding future research and practical disinfection to control the spread of ARGs and ARB in aquaculture.202134030387
7788130.9997Inactivation of antibiotic resistant Escherichia coli and degradation of its resistance genes by glow discharge plasma in an aqueous solution. Emerging contaminants such as antibiotic resistance bacteria (ARB) and antibiotic resistance genes (ARGs) are becoming a global environmental problem. In this study, the glow discharge plasma (GDP) was applied for degrading antibiotic resistant Escherichia coli (E. coli) with resistance genes (tetA, tetR, aphA) and transposase gene (tnpA) in 0.9% sterile saline. The results showed that GDP was able to inactivate the antibiotic resistant E. coli and remove the ARGs and reduce the risk of gene transfer. The levels of E. coli determined by 16S rRNA decreased by approximately 4.7 logs with 15 min of discharge treatment. Propidium monoazide - quantitative polymerase chain reaction (PMA-qPCR) tests demonstrated that the cellular structure of 4.8 more logs E. coli was destroyed in 15 min. The reduction of tetA, tetR, aphA, tnpA genes was increased to 5.8, 5.4, 5.3 and 5.5 logs with 30 min discharge treatment, respectively. The removal of ARGs from high salinity wastewater was also investigated. The total abundance of ARGs was reduced by 3.9 logs in 30 min. Scavenging tests indicated that hydroxyl radicals (·OH) was the most probable agents for bacteria inactivation and ARGs degradation. In addition, the active chlorine (Cl· and Cl(2)) which formed during the discharge may also contribute to the inactivation and degradation.202032229364
8005140.9997Deciphering the fate of antibiotic resistance genes in norfloxacin wastewater treated by a bio-electro-Fenton system. The misuse of antibiotics has increased the prevalence of antibiotic resistance genes (ARGs), considered a class of critical environmental contaminants due to their ubiquitous and persistent nature. Previous studies reported the potentiality of bio-electro-Fenton processes for antibiotic removal and ARGs control. However, the production and fate of ARGs in bio-electro-Fenton processes triggered by microbial fuel cells are rare. In this study, the norfloxacin (NFLX) average residual concentrations within two days were 2.02, 6.07 and 14.84 mg/L, and the average removal efficiency of NFLX was 79.8 %, 69.6 % and 62.9 % at the initial antibiotic concentrations of 10, 20 and 40 mg/L, respectively. The most prevalent resistance gene type in all processes was the fluoroquinolone antibiotic gene. Furthermore, Proteobacteria was the dominant ARG-carrying bacteria. Overall, this study can provide theoretical support for the efficient treatment of high antibiotics-contained wastewater by bio-electro-Fenton systems to better control ARGs from the perspective of ecological security.202236252757
7765150.9997Antibiotic resistance bacteria and antibiotic resistance genes survived from the extremely acidity posing a risk on intestinal bacteria in an in vitro digestion model by horizontal gene transfer. Antibiotic resistance bacteria (ARB) and antibiotic resistance genes (ARGs) are emerging contaminants posing risk to human health. To investigate the pathogenic ARBs and the horizontal gene transfer (HGT) via both extracellular ARGs (eARGs) and intracellular ARGs (iARGs), an in vitro digestion simulation system was established to monitoring the ARB and ARGs passing through the artificial digestive tract. The results showed that ARB was mostly affected by the acidity of the gastric fluid with about 99% ARB (total population of 2.45 × 10(9)-2.54 × 10(9)) killed at pH 2.0 and severe damage of bacterial cell membrane. However, more than 80% ARB (total population of 2.71 × 10(9)-3.90 × 10(9)) survived the challenge when the pH of the gastric fluid was 3.0 and above. Most ARB died from the high acidity, but its ARGs, intI1 and 16 S rRNA could be detected. The eARGs (accounting for 0.03-24.56% of total genes) were less than iARGs obviously. The eARGs showed greater HGT potential than that of iARGs, suggesting that transformation occurred more easily than conjugation. The transferring potential followed: tet (100%) > sul (75%) > bla (58%), related to the high correlation of intI1 with tetA and sul2 (p < 0.01). Moreover, gastric juice of pH 1.0 could decrease the transfer frequency of ARGs by 2-3 order of magnitude compared to the control, but still posing potential risks to human health. Under the treatment of digestive fluid, ARGs showed high gene horizontal transfer potential, suggesting that food-borne ARBs pose a great risk of horizontal transfer of ARGs to intestinal bacteria.202236332408
7793160.9997Treatment of pharmaceutical wastewater by ionizing radiation: Removal of antibiotics, antimicrobial resistance genes and antimicrobial activity. In present study, the treatment of real pharmaceutical wastewater from an erythromycin (ERY) production factory by gamma irradiation was investigated. Results showed that a variety of antimicrobial resistance genes (ARGs), involving MLSB, tet, bla, multidrug, sul, MGEs and van genes and plentiful 9 bacterial phyla were identified in the raw wastewater. In addition to ERY, sulfamethoxazole (SMX) and tetracycline (TC) were also identified with the concentration of 3 order of magnitude lower than ERY. Results showed that the abatement of ARGs and antibiotics was much higher than that of antimicrobial activity and COD. With the absorbed dose of 50 kGy, the removal percentage of ARGs, ERY, antimicrobial activity and COD was 96.5-99.8%, 90.0%, 47.8% and 10.3%, respectively. The culturable bacteria were abated fast and completely at 5.0 kGy during gamma irradiation. The genus Pseudomonas was predominant in raw wastewater (56.7%) and its relative abundance decreased after gamma irradiation, to 1.3% at 50 kGy. With addition of peroxymonosulfate (PMS, 50 mM), the antimicrobial activity disappeared completely and ERY removal reached as high as 99.2% at the lower absorbed dose of 25 kGy. Ionizing radiation-coupled technique is a potential option to treat pharmaceutical wastewater for reduction of antibiotics, ARGs and antimicrobial activity.202134088196
7184170.9997Effects of activated sludge and UV disinfection processes on the bacterial community and antibiotic resistance profile in a municipal wastewater treatment plant. Wastewater tertiary treatment has been pointed out as an effective alternative for reducing the concentration of antibiotic resistant bacteria and genes (ARB and ARGs) in wastewaters. The present work aimed to build on the current knowledge about the effects of activated sludge and UV irradiation on antibiotic resistance determinants in biologically treated wastewaters. For that, the microbial community and ARGs' composition of samples collected after preliminary (APT), secondary (AST), and tertiary (ATT) treatments in a full-scale wastewater treatment plant using a modified activated sludge (MAS) system followed by an UV stage (16 mJ/cm(2)) were investigated through culture-dependent and independent approaches (including metagenomics). A total of 24 phyla and 460 genera were identified, with predominance of Gammaproteobacteria in all samples. Pathogenic genera corresponded to 8.6% of all sequences on average, mainly Acinetobacter and Streptococcus. Significant differences (p < 0.05) in the proportion of pathogens were observed between APT and the other samples, suggesting that the secondary treatment reduced its abundance. The MAS achieved 64.0-99.7% average removal efficiency for total (THB) and resistant heterotrophic bacteria, although the proportions of ARB/THB have increased for sulfamethoxazole, cephalexin, ciprofloxacin, and tetracycline. A total of 10(7) copies/mL of intI1 gene remained in the final effluent, suggesting that the treatment did not significantly remove this gene and possibly other ARGs. In accordance, metagenomic results suggested that number of reads recruited to plasmid-associated ARGs became more abundant in the pool throughout the treatment, suggesting that it affected more the bacteria without these ARGs than those with it. In conclusion, disinfected effluents are still a potential source for ARB and ARGs, which highlights the importance to investigate ways to mitigate their release into the environment.202235060061
7571180.9997Ancient Oriental Wisdom still Works: Removing ARGs in Drinking Water by Boiling as compared to Chlorination. Antibiotic resistance genes (ARGs) in municipal drinking water may not be effectively removed during centralized treatment. To reduce potential health risks, water disinfection at the point-of-use scale is warranted. This study investigated the performance of boiling, a prevalent household water disinfection means, in response to ARGs contamination. We found that boiling was more efficient in inactivating both Escherichia coli and environmental bacteria compared to chlorination and pasteurization. Boiling of environmental bacteria suspension removed a much broader spectrum of ARGs and mobile genetic elements (up to 141 genes) than chlorination (up to 13 genes), such better performance was largely attributed to a stronger inactivation of chlorine-tolerant bacteria including Acinetobacter and Bacillus. Accumulation of extracellular ARGs was found during low-temperature heating (≤ 80°C) and in the initial stage of chlorination (first 3 min when initial chlorine was 5 mg/L and first 12 min when initial chlorine was 1 mg/L). These extracellular ARGs as well as the intracellular ARGs got removed as the heating temperature increased or the chlorination time prolonged. Under the same treatment time (30 min), high-temperature heating (≥ 90.1°C) damaged the DNA structure more thoroughly than chlorination (5 mg/L). Taking into account the low transferability of ARGs after DNA melting, boiling may provide an effective point-of-use approach to attenuating bacterial ARGs in drinking water and is still worth promoting in the future.202234910990
7807190.9997Copper oxide/peroxydisulfate system for urban wastewater disinfection: Performances, reactive species, and antibiotic resistance genes removal. In this study, copper oxide (CuO) catalyzed peroxydisulfate (PDS) system was investigated for the inactivation of a broad range of pathogenic microorganisms from urban wastewater. Complete inactivation of Escherichia coli, Enterococcus, F-specific RNA bacteriophages from secondary treated wastewater was achieved after a short time (15-30 min) treatment with CuO (10 g/L)/PDS (1 mM) system, but spores of sulfite-reducing bacteria took 120 min. No bacterial regrowth occurred during storage after treatment. Significant reduction of the pathogens was explained by the generation of the highly selective Cu(III) oxidant, as the predominant reactive species, which could quickly oxidize guanine through a one-electron oxidation pathway. Additionally, the potential of the CuO (10 g/L)/PDS (1 mM) system to inactivate antibiotic-resistant bacteria and antibiotic resistance genes (ARB&Gs) was explored. Sulfamethoxazole-resistant E. coli was used as the model ARB and a 3.2 log of reduction was observed after 10 min of treatment. A considerable reduction (0.7-2.3 log) of selected ARGs including blaTEM, qnrS, emrB, sul1, and genes related to the dissemination of antibiotic resistance, including the Class 1 integron-integrase (intI1), and the insertion sequence (IS613) was achieved after 60 min treatment. All these findings indicated the promising applicability of the CuO/PDS system as a disinfection technology for wastewater reuse in agriculture.202234648831