# | Rank | Similarity | Title + Abs. | Year | PMID |
|---|---|---|---|---|---|
| 0 | 1 | 2 | 3 | 4 | 5 |
| 1486 | 0 | 1.0000 | Multicenter evaluation of the Verigene Gram-negative blood culture nucleic acid test for rapid detection of bacteria and resistance determinants in positive blood cultures. The Verigene Gram-Negative Blood Culture Nucleic Acid Test (BC-GN) is a microarray-based assay that enables rapid detection of 9 common Gram-negative bacteria and 6 resistance determinants directly from positive blood cultures. We compared the performance of BC-GN with currently used automated systems, testing 141 clinical blood cultures and 205 spiked blood cultures. For identification of BC-GN target organisms in clinical and spiked blood cultures, the BC-GN assay showed 98.5% (130/132) and 98.9% (182/184) concordance, respectively. Of 140 resistance genes positively detected in clinical and spiked blood cultures with the BC-GN test, 139 (99.3%) were confirmed by PCR, and the detection results were consistent with the resistance phenotypes observed. The BC-GN assay, thus, can potentially improve care for sepsis patients by enabling timely detection and targeted antimicrobial therapy. | 2015 | 26361710 |
| 1490 | 1 | 0.9998 | Rapid detection of Gram-negative bacteria and their drug resistance genes from positive blood cultures using an automated microarray assay. We evaluated the performance of the Verigene Gram-negative blood culture (BC-GN) assay (CE-IVD version) for identification of Gram-negative (GN) bacteria and detection of resistance genes. A total of 163 GN organisms (72 characterized strains and 91 clinical isolates from 86 patients) were tested; among the clinical isolates, 86 (94.5%) isolates were included in the BC-GN panel. For identification, the agreement was 98.6% (146/148, 95% confidence interval [CI], 92.1-100) and 70% (7/10, 95% CI, 53.5-100) for monomicrobial and polymicrobial cultures, respectively. Of the 48 resistance genes harbored by 43 characterized strains, all were correctly detected. Of the 19 clinical isolates harboring resistance genes, 1 CTX-M-producing Escherichia coli isolated in polymicrobial culture was not detected. Overall, BC-GN assay provides acceptable accuracy for rapid identification of Gram-negative bacteria and detection of resistance genes, compared with routine laboratory methods despite that it has limitations in the number of genus/species and resistance gene included in the panel and it shows lower sensitivity in polymicrobial cultures. | 2015 | 25591999 |
| 1478 | 2 | 0.9998 | Multicenter Evaluation of the FilmArray Blood Culture Identification 2 Panel for Pathogen Detection in Bloodstream Infections. The FilmArray Blood Culture Identification 2 panel (BCID2; bioMérieux) is a fully automated PCR-based assay for identifying bacteria, fungi, and bacterial resistance markers in positive blood cultures (BC) in about 1 h. In this multicenter study, we evaluated the performance of the BCID2 panel for pathogen detection in positive BC. Conventional culture and BCID2 were performed in parallel at four tertiary-care hospitals. We included 152 positive BC-130 monomicrobial and 22 polymicrobial cultures-in this analysis. The BCID2 assay correctly identified 90% (88/98) of Gram-negative and 89% (70/79) of Gram-positive bacteria. Five bacterial isolates targeted by the BCID2 panel and recovered from five positive BC, including three polymicrobial cultures, were missed by the BCID2 assay. Fifteen isolates were off-panel organisms, accounting for 8% (15/182) of the isolates obtained from BC. The mean positive percent agreement between the BCID2 assay and standard culture was 97% (95% confidence interval, 95 to 99%), with agreement ranging from 67% for Candida albicans to 100% for 17 targets included in the BCID2 panel. BCID2 also identified the bla(CTX-M) gene in seven BC, including one for which no extended-spectrum β-lactamase (ESBL)-producing isolate was obtained in culture. However, it failed to detect ESBL-encoding genes in three BC. Two of the 18 mecA/C genes detected by the BCID2 were not confirmed. No carbapenemase, mecA/C, or MREJ targets were detected. The median turnaround time was significantly shorter for BCID2 than for culture. The BCID2 panel may facilitate faster pathogen identification in bloodstream infections. IMPORTANCE Rapid molecular diagnosis combining the identification of pathogens and the detection of antibiotic resistance genes from positive blood cultures (BC) can improve the outcome for patients with bloodstream infections. The FilmArray BCID2 panel, an updated version of the original BCID, can detect 11 Gram-positive bacteria, 15 Gram-negative bacteria, 7 fungal pathogens, and 10 antimicrobial resistance genes directly from a positive BC. Here, we evaluated the real-life microbiological performance of the BCID2 assay in comparison to the results of standard methods used in routine practice at four tertiary care hospitals. | 2023 | 36519852 |
| 1485 | 3 | 0.9998 | Evaluation of Verigene Blood Culture Test Systems for Rapid Identification of Positive Blood Cultures. The performance of molecular tests using the Verigene Gram-Positive and Gram-Negative Blood Culture nucleic acid tests (BC-GP and BC-GN, resp.; Naosphere, Northbrook, IL, USA) was evaluated for the identification of microorganisms detected from blood cultures. Ninety-nine blood cultures containing Gram-positive bacteria and 150 containing Gram-negative bacteria were analyzed using the BC-GP and BC-GN assays, respectively. Blood cultures were performed using the Bactec blood culture system (BD Diagnostic Systems, Franklin Lakes, NJ, USA) and conventional identification and antibiotic-susceptibility tests were performed using a MicroScan system (Siemens, West Sacramento, CA, USA). When a single strain of bacteria was isolated from the blood culture, Verigene assays correctly identified 97.9% (94/96) of Gram-positive bacteria and 93.8% (137/146) of Gram-negative bacteria. Resistance genes mecA and vanA were correctly detected by the BC-GP assay, while the extended-spectrum β-lactamase CTX-M and the carbapenemase OXA resistance gene were detected from 30 cases cultures by the BC-GN assay. The BC-GP and BC-GN assays showed high agreement with conventional identification and susceptibility tests. These tests are useful for rapid identification of microorganisms and the detection of clinically important resistance genes from positive Bactec blood cultures. | 2016 | 26904669 |
| 2236 | 4 | 0.9998 | Development of a Multiplex PCR Platform for the Rapid Detection of Bacteria, Antibiotic Resistance, and Candida in Human Blood Samples. The diagnosis of bloodstream infections (BSIs) still relies on blood culture (BC), but low turnaround times may hinder the early initiation of an appropriate antimicrobial therapy, thus increasing the risk of infection-related death. We describe a direct and rapid multiplex PCR-based assay capable of detecting and identifying 16 bacterial and four Candida species, as well as three antibiotic-resistance determinants, in uncultured samples. Using whole-blood samples spiked with microorganisms at low densities, we found that the MicrobScan assay had a mean limit of detection of 15.1 ± 3.3 CFU of bacteria/Candida per ml of blood. When applied to positive BC samples, the assay allowed the sensitive and specific detection of BSI pathogens, including bla(KPC)-, mecA-, or vanA/vanB-positive bacteria. We evaluated the assay using prospectively collected blood samples from patients with suspected BSI. The sensitivity and specificity were 86.4 and 97.0%, respectively, among patients with positive BCs for the microorganisms targeted by the assay or patients fulfilling the criteria for infection. The mean times to positive or negative assay results were 5.3 ± 0.2 and 5.1 ± 0.1 h, respectively. Fifteen of 20 patients with MicrobScan assay-positive/BC-negative samples were receiving antimicrobial therapy. In conclusion, the MicrobScan assay is well suited to complement current diagnostic methods for BSIs. | 2019 | 31799215 |
| 1484 | 5 | 0.9997 | Use of a commercial PCR-based line blot method for identification of bacterial pathogens and the mecA and van genes from BacTAlert blood culture bottles. In this study, the PCR-based DNA strip assay GenoType BC for the identification of bacteria and the resistance genes mecA, vanA, vanB, vanC1, and vanC2/3 directly from positive BacTAlert blood culture bottles was evaluated in a multicenter study. Of a total of 511 positive blood cultures, correct identification percentages for Gram-negative bacteria, Gram-positive bacteria, and the mecA gene were 96.1%, 89.9%, and 92.9%, respectively. Results were available 4 h after growth detection. | 2012 | 22075585 |
| 1477 | 6 | 0.9997 | Multicenter Evaluation of the BIOFIRE Blood Culture Identification 2 Panel for Detection of Bacteria, Yeasts, and Antimicrobial Resistance Genes in Positive Blood Culture Samples. Diagnostic tools that can rapidly identify and characterize microbes growing in blood cultures are important components of clinical microbiology practice because they help to provide timely information that can be used to optimize patient management. This publication describes the bioMérieux BIOFIRE Blood Culture Identification 2 (BCID2) Panel clinical study that was submitted to the U.S. Food & Drug Administration. Results obtained with the BIOFIRE BCID2 Panel were compared to standard-of-care (SoC) results, sequencing results, PCR results, and reference laboratory antimicrobial susceptibility testing results to evaluate the accuracy of its performance. Results for 1,093 retrospectively and prospectively collected positive blood culture samples were initially enrolled, and 1,074 samples met the study criteria and were included in the final analyses. The BIOFIRE BCID2 Panel demonstrated an overall sensitivity of 98.9% (1,712/1,731) and an overall specificity of 99.6% (33,592/33,711) for Gram-positive bacteria, Gram-negative bacteria and yeast targets which the panel is designed to detect. One hundred eighteen off-panel organisms, which the BIOFIRE BCID2 Panel is not designed to detect, were identified by SoC in 10.6% (114/1,074) of samples. The BIOFIRE BCID2 Panel also demonstrated an overall positive percent agreement (PPA) of 97.9% (325/332) and an overall negative percent agreement (NPA) of 99.9% (2,465/2,767) for antimicrobial resistance determinants which the panel is designed to detect. The presence or absence of resistance markers in Enterobacterales correlated closely with phenotypic susceptibility and resistance. We conclude that the BIOFIRE BCID2 Panel produced accurate results in this clinical trial. | 2023 | 37227281 |
| 2234 | 7 | 0.9997 | Clinical relevance of molecular identification of microorganisms and detection of antimicrobial resistance genes in bloodstream infections of paediatric cancer patients. BACKGROUND: Bloodstream infections (BSIs) are the major cause of mortality in cancer patients. Molecular techniques are used for rapid diagnosis of BSI, allowing early therapy and improving survival. We aimed to establish whether real-time quantitative polymerase chain reaction (qPCR) could improve early diagnosis and therapy in paediatric cancer patients, and describe the predominant pathogens of BSI and their antimicrobial susceptibility. METHODS: Blood samples were processed by the BACTEC system and microbial identification and susceptibility tests were performed by the Phoenix system. All samples were screened by multiplex 16 s rDNA qPCR. Seventeen species were evaluated using sex-specific TaqMan probes and resistance genes blaSHV, blaTEM, blaCTX, blaKPC, blaIMP, blaSPM, blaVIM, vanA, vanB and mecA were screened by SYBR Green reactions. Therapeutic efficacy was evaluated at the time of positive blood culture and at final phenotypic identification and antimicrobial susceptibility results. RESULTS: We analyzed 69 episodes of BSI from 64 patients. Gram-positive bacteria were identified in 61 % of the samples, Gram-negative bacteria in 32 % and fungi in 7 %. There was 78.2 % of agreement between the phenotypic and molecular methods in final species identification. The mecA gene was detected in 81.4 % of Staphylococcus spp., and 91.6 % were concordant with the phenotypic method. Detection of vanA gene was 100 % concordant. The concordance for Gram-negative susceptibilities was 71.4 % for Enterobacteriaceae and 50 % for Pseudomonas aeruginosa. Therapy was more frequently inadequate in patients who died, and the molecular test was concordant with the phenotypic susceptibility test in 50 %. CONCLUSIONS: qPCR has potential indication for early identification of pathogens and antimicrobial resistance genes from BSI in paediatric cancer patients and may improve antimicrobial therapy. | 2016 | 27585633 |
| 1479 | 8 | 0.9997 | BioFire FilmArray BCID2 versus VITEK-2 System in Determining Microbial Etiology and Antibiotic-Resistant Genes of Pathogens Recovered from Central Line-Associated Bloodstream Infections. Central line-associated bloodstream infection (CLABSI) is among the most serious hospital acquired infections. Therefore, the rapid detection of the causative microorganism is of crucial importance to allow for the appropriate antimicrobial therapy. In the present study, we analyzed the clinical performance of the BioFire FilmArray Blood Culture Identification 2 (BCID2) panel in the identification of 33 microbial species and 10 antibiotic resistance genes in comparison to the VITEK-2 system. A total of 104 blood specimens were included. The FilmArray BCID2 results were concordant with the VITEK-2 system in 69/97 specimens (71.1%). Non-concordance was either due to the detection of more pathogens by the FilmArray BCID2 23/28 (82%) or microbial species were misidentified 5/28 (18%). Hence, in comparison to the VITEK-2 system, the FilmArray BCID2 panel showed an overall sensitivity of 75.8% (95% CI, 66-83%) and an overall specificity of 98% (95% CI, 97-98.8%) in detecting microbial species. For the resistance genes, the FilmArray BCID was able to detect the presence of blaCTX-M gene in 23 Gram-negative isolates, blaNDM and blaOXA-48- like genes in 14 and 13 isolates, respectively. The mecA and mecC genes were found in 23 Staphylococcus species, while mecA, mecC and MREJ genes were found in 4 Staphylococcus aureus isolates. The sensitivity and specificity for detecting resistance genes by the FilmArray BCID2 was 90% (95% CI, 81.4-95%) and 99.6% (95% CI, 99-100%), respectively. As concluded, the present study emphasizes the high sensitivity and specificity of the FilmArray BCID2 in the rapid and reliable detection of different bacteria and fungi from positive blood culture bottles, as well as the accurate detection of various antibiotic resistance markers. | 2022 | 36358274 |
| 2237 | 9 | 0.9996 | Evaluation of Sepsis Flow Chip for identification of Gram-negative bacilli and detection of antimicrobial resistance genes directly from positive blood cultures. Blood stream infections are serious conditions associated with high morbi-mortality. In this study, the new Sepsis Flow Chip (SFC) assay for identification of Gram-negative bacteria and their antimicrobial resistance genes was evaluated in positive blood cultures (BCs). SFC is a microarray with a broad panel comprising the most frequent causative agents of sepsis and antimicrobial resistance genes associated with them. A total of 100 prospective BCs, positive for Gram-negative bacilli, were assessed in the routine of the clinical microbiology laboratory and also applying the SFC assay. Moreover, 19 BCs spiked with well-characterized enterobacterial isolates, harboring antimicrobial resistance genes, were analyzed by the latter. Among the monomicrobial BCs (90), the concordance between SFC identification and the reference method was 94.4%; however, it achieved 100% when SFC was combined with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry after 4-h incubation. Regarding polymicrobial BCs (10), 15 out of the 22 bacteria present (68.2%) were correctly identified, including all contained in 50% of the cultures. With regard to antimicrobial resistance genes, 98.8%, 98.9%, and 99% concordance was obtained for bla(CTX-M), bla(OXA-48), and bla(VIM), respectively, in comparison with polymerase chain reaction amplification. SFC assay gives results in only 4 h and showed a high concordance rate with the reference method. Although further evaluation studies are necessary, SFC assay implementation, together with antimicrobial stewardship programs, could contribute to improve the therapeutic approaches and to reduce the morbi-mortality, length of hospital stay, and healthcare-associated costs in patients with sepsis. | 2018 | 29551362 |
| 5798 | 10 | 0.9996 | Rapid identification of bacteria, mecA and van genes from blood cultures. The Genotype technology, a quick molecular genetic assay based on DNA multiplex amplification with biotinylated primers followed by hybridization to membrane bound probes, complies with the requirements for a fast diagnosis of sepsis. We evaluated the new Genotype BC Gram-negative and Gram-positive test kits (Hain Life Science, Germany) which respectively allow for the identification of 15 species of Gram-negative (GN) rods, and the identification of 17 Gram-positive (GP) bacteria species together with the determination of methicillin and vancomycin resistance (mecA and van genes). The study was performed on 60 positive blood cultures from BacT/ALERT bottles (aerobic, anaerobic and pediatric bottles). First, a Gram stain was carried out to select between Genotype BC GP or GN test, then identification were performed by the Genotype BC tests and by biochemical conventional tests after subculture and phenotypic susceptibility determination. The operating procedure was very easy to carry out and required a small amount of starting material (5 to 10 microL of blood culture). The results were available within 4.5 hours. For all the blood cultures, the Genotype BC results correlated with the biochemical identification and phenotypic antibiotics susceptibility. According to our results, this DNA strip technology based assay can easily be incorporated into routine diagnosis. | 2007 | 17913394 |
| 2220 | 11 | 0.9996 | Rapid detection and molecular survey of blaVIM, blaIMP and blaNDM genes among clinical isolates of Acinetobacter baumannii using new multiplex real-time PCR and melting curve analysis. BACKGROUND: Acinetobacter baumannii is a cosmopolitan bacterium that is frequently reported from hospitalized patients, especially those patients who admitted in the intensive care unit. Recently, multiplex real-time PCR has been introduced for rapid detection of the resistance genes in clinical isolates of bacteria. The current study aimed to develop and evaluate multiplex real-time PCR to detect common resistance genes among clinical isolates of A. baumannii. RESULTS: Multiplex real-time PCR based on melting curve analysis showed different T(m) corresponding to the amplified fragment consisted of 83.5 °C, 93.3 °C and 89.3 °C for blaIMP, blaVIM and blaNDM, respectively. Results of multiplex real-time PCR showed that the prevalence of blaIMP, blaVIM and blaNDM among the clinical isolates of A. baumannii were 5/128(3.9%), 9/128(7.03%) and 0/128(0%), respectively. Multiplex real-time PCR was able to simultaneously identify the resistance genes, while showed 100% concordance with the results of conventional PCR. CONCLUSIONS: The current study showed that blaVIM, was the most prevalent MBL gene among the clinical isolates of A. baumannii while no amplification of blaNDM was seen. Multiplex real-time PCR can be sensitive and reliable technique for rapid detection of resistance genes in clinical isolates. | 2019 | 31182026 |
| 2235 | 12 | 0.9996 | Nanosphere's Verigene(®) Blood Culture Assay to Detect Multidrug-Resistant Gram-Negative Bacterial Outbreak: A Prospective Study on 79 Hematological Patients in a Country with High Prevalence of Antimicrobial Resistance. Infections are a major cause of morbidity and mortality in hematological patients. We prospectively tested a new molecular assay (Verigene(®)) in 79 consecutive hematological patients, with sepsis by gram-negative bacteria. A total of 82 gram-negative microorganisms were isolated by blood cultures, of which 76 cases were mono-microbial. Considering the bacteria detectable by the system, the concordance with standard blood cultures was 100%. Resistance genes were detected in 20 of the isolates and 100% were concordant with the phenotypic antibiotic resistance. Overall, this new assay correctly identified 66/82 of all the gram-negative pathogens, yielding a general sensitivity of 80.5%, and providing information on genetic antibiotic resistance in a few hours. This new molecular assay could ameliorate patient management, resulting in a more rational use of antibiotics. | 2019 | 34595420 |
| 1491 | 13 | 0.9996 | Evaluation of an expanded antibiotic resistance gene panel on prediction of antimicrobial susceptibility results for Gram-negative bacteria in blood cultures. The QIAstat-Dx BCID Panels (RUO) ("QIAstat," QIAGEN, Hilden, Germany) for identification of 13 Gram-negative bacteria and 18 antimicrobial resistance (AMR) gene groups was evaluated. The study was conducted in two phases; in phase 1, analytical performance was evaluated against 154 challenge isolates against whole genome sequencing data. In this phase, sensitivity and specificity of organism identification calls were 153/154 (99.3%) and 1,748/1,749 (99.8%), respectively. For AMR genes, sensitivity was 434/435 (99.8%) and specificity was 2,334/2,337 (99.9%). One false-negative bla(IMP), one false-positive bla(CTX-M), and two false-positive aac-6'-lb detections were noted in this challenge set of organisms. In phase 2, 101 clinical blood culture isolates of Gram-negative rods were evaluated by the multiplexed PCR versus reference broth microdilution, for the ability of identification combined with AMR genes to predict final susceptibility results. Negative predictive values were 92.8% for ampicillin resistance (100% for Escherichia coli), 93.4% for ceftriaxone, 97.4% for ceftazidime, and 98.7% for cefepime. In constrast, negative predictive values for current standard of care (identification plus detection of bla(CTX-M)) ranged from 56.5% to 88.8%. This study demonstrated additive value of additional beta-lactamase genes for bacteria isolated from blood cultures. IMPORTANCE: Prediction of Gram-negative bacteria resistance through detection of resistance genes is complex. This study evaluated a novel, direct-from-blood or bacterial isolate multiplexed PCR for the detection of 17 resistance genes, and evaluated the prediction of antimicrobial susceptibility. | 2024 | 39297627 |
| 2238 | 14 | 0.9996 | Rapid detection of carbapenem resistance among gram-negative organisms directly from positive blood culture bottles. BACKGROUND: Carbapenemase producing gram-negative bacteria (GNB) has become a huge problem in majority of tertiary care centers worldwide. They are associated with very high morbidity and mortality rates, especially when they cause invasive infections. Therefore, rapid detection of these organisms is very important for prompt and adequate antibiotic therapy as well as infection control. The aim of this study was rapid detection of carbapenemase genes and thereby likely carbapenem resistance, 24-48 hours in advance, directly from the positive-flagged blood culture bottles using CHROMagar and Xpert® Carba-R. METHODS: Aspirate from positively flagged blood culture bottles was subjected to differential centrifuge. All gram-negative bacilli on gram stain from the deposit were processed in Xpert® Carba-R and inoculated on CHROMagar. The presence of genes and growth on CHROMagar was compared with carbapenem resistance on VITEK-2 Compact. RESULTS: A total of 119 GNB isolates were processed. One or more of the carbapenemase genes were detected in 80 isolates. On comparison with VITEK-2 result, 92 samples showed concordance for carbapenem resistance 48 hours in advance. There was discordance in 21 isolates with 12 major errors and 09 minor errors. The sensitivity of direct Xpert® Carba-R test for rapid detection of carbapenem resistance, 48 hours in advance, was 81.42%. The sensitivity of direct CHROMagar test for accurate detection of carbapenem resistance, 24 hours in advance, was 92.06%. CONCLUSION: The ability to detect carbapenem resistance with very high accuracy, 48 hours in advance, helps in appropriate antibiotic therapy and implementation of effective infection control practices. | 2023 | 37193528 |
| 1488 | 15 | 0.9996 | Evaluation of an automated rapid diagnostic assay for detection of Gram-negative bacteria and their drug-resistance genes in positive blood cultures. We evaluated the performance of the Verigene Gram-Negative Blood Culture Nucleic Acid Test (BC-GN; Nanosphere, Northbrook, IL, USA), an automated multiplex assay for rapid identification of positive blood cultures caused by 9 Gram-negative bacteria (GNB) and for detection of 9 genes associated with β-lactam resistance. The BC-GN assay can be performed directly from positive blood cultures with 5 minutes of hands-on and 2 hours of run time per sample. A total of 397 GNB positive blood cultures were analyzed using the BC-GN assay. Of the 397 samples, 295 were simulated samples prepared by inoculating GNB into blood culture bottles, and the remaining were clinical samples from 102 patients with positive blood cultures. Aliquots of the positive blood cultures were tested by the BC-GN assay. The results of bacterial identification between the BC-GN assay and standard laboratory methods were as follows: Acinetobacter spp. (39 isolates for the BC-GN assay/39 for the standard methods), Citrobacter spp. (7/7), Escherichia coli (87/87), Klebsiella oxytoca (13/13), and Proteus spp. (11/11); Enterobacter spp. (29/30); Klebsiella pneumoniae (62/72); Pseudomonas aeruginosa (124/125); and Serratia marcescens (18/21); respectively. From the 102 clinical samples, 104 bacterial species were identified with the BC-GN assay, whereas 110 were identified with the standard methods. The BC-GN assay also detected all β-lactam resistance genes tested (233 genes), including 54 bla(CTX-M), 119 bla(IMP), 8 bla(KPC), 16 bla(NDM), 24 bla(OXA-23), 1 bla(OXA-24/40), 1 bla(OXA-48), 4 bla(OXA-58), and 6 blaVIM. The data shows that the BC-GN assay provides rapid detection of GNB and β-lactam resistance genes in positive blood cultures and has the potential to contributing to optimal patient management by earlier detection of major antimicrobial resistance genes. | 2014 | 24705449 |
| 2231 | 16 | 0.9995 | Detection of the common resistance genes in Gram-negative bacteria using gene chip technology. OBJECTIVE: To design a resistance gene detection chip that could, in parallel, detect common clinical drug resistance genes of Gram-negative bacteria. MATERIALS AND METHODS: Seventy clinically significant Gram-negative bacilli (Klebsiella pneumoniae, Escherichia coli, Enterobacter cloacae, Pseudomonas aeruginosa, Acinetobacter baumannii) were collected. According to the known resistance gene sequences, we designed and synthesized primers and probes, which were used to prepare resistance gene detection chips, and finally we hybridized and scanned the gene detection chips. RESULTS: The results between the gene chip and polymerase chain reaction (PCR) were compared. The rate was consistently 100% in the eight kinds of resistance genes tested (TEM, SHV, CTX-M, DHA, CIT, VIM, KPC, OXA-23). One strain of Pseudomonas aeruginosa had the IMP, but it was not found by gene chip. CONCLUSION: The design of Gram-negative bacteria-resistant gene detection chip had better application value. | 2013 | 23867670 |
| 2226 | 17 | 0.9995 | Evaluation of the Microbiological Performance and Potential Clinical Impact of New Rapid Molecular Assays for the Diagnosis of Bloodstream Infections. Bloodstream infection (BSI) is a critical medical emergency associated with a high mortality rate. Rapid and accurate identification of the causative pathogen and the results of antimicrobial susceptibility testing are crucial for initiating appropriate antimicrobial therapy. The aim of this study was to evaluate the performance of a new rapid PCR Molecular Mouse System (MMS) for the identification of Gram-negative bacteria (GNB) and GNB resistance genes directly from a positive blood culture (BC). The validation of these rapid multiplex assays was carried out in a real hospital setting. A total of 80 BSI episodes were included in our study and the results were compared with culture-based methods. BC samples in which GNB had previously been detected microscopically and which originated from different hospital wards were analysed. The MMS GNB identification assay achieved a sensitivity of 98.7% and a specificity of 100% for the covered pathogens. In one BC sample, Klebsiella aerogenes was identified at the family level (Enterobacteriaceae) with MMS. However, in three polymicrobial samples, MMS identified bacteria that were not detected by culture-based methods (Klebsiella pneumoniae, K. aerogenes and Stenotrophomonas maltophilia). MMS also showed excellent overall performance in the detection of GNB resistance markers (100% sensitivity and 100% specificity). The type of extended-spectrum beta-lactamase (ESBL) resistance gene identified correctly with MMS was CTX-M-1/9 (n = 17/20), alone or in combination with SHV-type β-lactamase or with the different types of carbapenemase genes. MMS detected one carbapenemase gene of each type (KPC, NDM and OXA-23) and six OXA-48 genes. In addition, the colistin resistance gene mcr-1 was detected in one positive BC with Escherichia coli (E. coli). The time to result was significantly shorter for MMS than for routine culture methods. A retrospective analysis of the patients' medical records revealed that a change in empirical antimicrobial therapy would have been made in around half of the patients following the MMS results. These results support the use of MMS as a valuable complement to conventional culture methods for more rapid BSI diagnosis and adjustment of empirical therapy. | 2025 | 40142509 |
| 1489 | 18 | 0.9995 | Direct detection of mecA, bla(SHV) , bla(CTX)(-M) , bla(TEM) and bla(OXA) genes from positive blood culture bottles by multiplex-touchdown PCR assay. Methicillin-resistant staphylococci (MRS) and ESBL(Extended-Spectrum β-Lactamase)-producing bacteria are the most important resistant pathogens in sepsis. In this study, a new multiplex-touchdown PCR method (MT-PCR) was developed to detect rapidly and simultaneously the presence of mecA, bla(SHV) , bla(CTX)(-M) , bla(TEM) and bla(OXA) genes from positive blood culture bottles. The technique showed a sensitivity of 10(3 ) CFU ml(-1) for mecA detection and of 10(2) CFU ml(-1) for other genes, and 100% specificity in the detection of all genes. All genes were detected in the spiked blood culture bottles artificially contaminated with reference strains. Three methicillin-resistant S. aureus (MRSA), two methicillin-resistant S. epidermidis (MRSE) and 32 ESBL-producing bacteria, were isolated from the clinical blood culture specimens in 48 h by standard microbiological procedures. The corresponding genes were detected directly in the three MRSA, two MRSE and 29 ESBL-producing bacteria from the clinical blood culture specimens in 4 h by MT-PCR assay. None of the bla(SHV) , bla(CTX)(-M) , bla(TEM) and bla(OXA) genes were detected in three other bottles with ESBL-producing bacteria because of other ESBL genotypes in the pathogens. Likewise, all bottles proven negative by culture remained negative by PCR. The proposed method was rapid, sensitive and specific, and was able to directly detect the genes of MRS and ESBL-producing bacteria from the blood culture bottles. SIGNIFICANCE AND IMPACT OF THE STUDY: Many studies on the development of PCR for the detection of resistance genes have already been published, including multiplex PCR methods. However, cross-amplification reactions can be a major concern in multiplex PCR methods. In this study, we developed a highly sensitive and specific multiplex-touchdown PCR assay for simultaneous detection of mecA, bla(SHV) , bla(CTX)(-M) , bla(TEM) and bla(OXA) genes from positive blood culture bottles, cross-amplification was absent and false-positive results were not obtained. | 2017 | 27699804 |
| 2213 | 19 | 0.9995 | The distribution and resistance of pathogens causing blood stream infections following liver transplantation: a clinical analysis of 69 patients. BACKGROUND/AIMS: To study the distribution and drug resistance of pathogens causing blood stream infections (BSIs) and provide the evidence for clinical therapy after liver transplantation. METHODOLOGY: Blood samples were processed by the BACTEC 9120 blood culture system. Species identification was performed using the Vitek-2 system. The drug susceptibility of pathogens was performed using the ATB FUNGUS 3 system. RESULTS: One hundred and twenty six episodes of BSIs occurred in 69 patients between January 31, 2003 and January 31, 2014. The gram-positive bacteria emerged as major pathogens and constituted 48.4% of all pathogens (61/126). The most common bacilli were Enterobacter spp and Enterococcus spp followed by S. aureus. The gram-negative bacteria were relatively sensitive to carbapenems and the gram-positive bacteria were relatively sensitive to glycopeptides and oxazolidone antibiotics. The drug resistance of fungi to amphotericin B, flucytosine, voriconazole and caspofungin was not found. CONCLUSION: In liver transplantation, gram-positive bacteria caused BSls more frequently than gram-negative bacteria. The resistance rate of bacteria to antibiotics was high while the rate was low in fungi. | 2014 | 25699372 |